EasyManua.ls Logo

Delta ASDA-M Series - Page 287

Delta ASDA-M Series
645 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 8 Parameters ASDA-M
8-56 Revision December, 2014
Unit
Pulse
Range
1 ~ 8000
Data Size
16bit
Format
DEC
Settings
When enabling the auto suppression (P1-29 = 1), it will
automatically search the detection level. The lower the value is,
the more sensitive the detection will be. However, it is easy to
misjudge the noise or regard the other low-frequency vibration as
the suppression frequency. If the value is bigger, it will make more
precise judgment. However, if the vibration of the mechanism is
smaller, it might not detect the frequency of low-frequency
vibration.
P1-31
Reserved
Address: 013EH
013FH
P1-32 LSTP Motor Stop Mode
Address: 0140H
0141H
Parameter
Attribute
Parameter for individual axis
Related Section: -
Operational
Interface
Panel / Software Communication
Default
0
Control
Mode
ALL
Unit
-
Range
0 ~ 0x20
Data Size
16bit
Format
HEX

Table of Contents

Other manuals for Delta ASDA-M Series

Related product manuals