ASDA-M Chapter 8 Parameters
Revision December, 2014 8-65
Settings:
If the setting is wrong, the servo motor will easily have sudden
unintended acceleration.
Please follow the rules for setting:
The setting of pulse input:
Range of command pulse input : 1/50<Nx/M<25600
NOTE
1) The setting value cannot be changed when Servo ON neither
in PT nor in PR mode.
P1-46▲
GR3 Pulse Number of Encoder Output
Address: 015CH
015DH
Parameter
Attribute:
Parameter for individual axis
Related Section: -
Operational
Interface:
Panel / Software Communication
Default:
2500
Control
Mode:
ALL
Unit:
Pulse
Range:
20 ~ 320000
Data Size:
32bit
Format:
DEC
Settings:
The number of pulse output per revolution.
NOTE
The following circumstances might exceed the max. allowable
input pulse frequency and occurs AL018:
1. Abnormal encoder
2. The motor speed is faster than the setting of P1-76.
3.
6
1019.8 4 461P
60
Speed Motor