ASDA-M Chapter 8 Parameters
Revision December, 2014 8-129
P4-04
ASH5 Fault Record (N-4)
Address: 0408H
0409H
Parameter
Attribute
Parameter for individual axis
Related Section:
Section 4.4.1
Operational
Interface
Panel / Software Communication
Default
0
Control
Mode
ALL
Unit
-
Range
-
Data Size
32bit
Format
HEX
Settings
The last fifth abnormal status record
Low word: LXXXX: display ALM number
High word: hYYYY: display the error code corresponds to
CANopen
P4-05 JOG Servo Motor Jog Control
Address: 040AH
040BH
Parameter
Attribute
Parameter for individual axis
Related Section:
Section 4.4.2
Operational
Interface
Panel / Software Communication
Default
20
Control
Mode
ALL
Unit
r/min
Range
0 ~ 5000
Data Size
16bit
Format
DEC