ASDA-M Chapter 9 Communication
9-6 Revision December, 2014
P3-02 PTL Communication Protocol
Address: 0304H
0305H
Parameter
Attribute:
Parameter for three axes
Related Section:
Section 9.2
Operational
Interface:
Panel / Software Communication
Default:
6
Control
Mode:
ALL
Unit:
-
Range:
0 ~ 0x8
Data Size:
16bit
Format:
HEX
Settings:
The definition of the setting value is as the followings:
0: 7, N, 2(MODBUS, ASCII)
1: 7, E, 1(MODBUS, ASCII)
2: 7, O, 1(MODBUS, ASCII)
3: 8, N, 2(MODBUS, ASCII)
4: 8, E, 1(MODBUS, ASCII)
5: 8, O, 1(MODBUS, ASCII)
6: 8, N, 2(MODBUS, RTU)
7: 8, E, 1(MODBUS, RTU)
8: 8, O, 1(MODBUS, RTU)
P3-03 FLT Communication Error Disposal
Address: 0306H
0307H
Parameter
Attribute:
Parameter for three axes
Related Section:
Section 9.2
Operational
Interface:
Panel / Software Communication
Default:
0
Control
Mode:
ALL
Unit:
-
Range:
0 ~ 0x1
Data Size:
16bit
Format:
HEX