Chapter 10 Troubleshooting ASDA-M
10-6 Revision December, 2014
AL131
CRC of
EEPROM
calculation
error occurs
when using
CANopen
PDO object
It indicates that the data
stored in ROM has been
damaged. All objects of
CAN will return to the
default setting
automatically.
Same as
above
ALM
Servo
On
AL132
Enter the
incorrect
password
when using
CANopen
PDO object
When entering
parameters via CAN, the
parameters are
password-protected.
Users have to decode
the password first.
Same as
above
ALM
Servo
On
AL185
Abnormal
CAN Bus
hardware
The communication of
CAN Bus is breakdown
or Error Rx/Tx Counter
is over 128.
NMTReset
node or
re-servo on
ALM
Servo
On