Chapter 10 Troubleshooting ASDA-M
10-32 Revision December, 2014
AL275: CRC of EEPROM calculation error occurs when using CANopen object
Causes Checking Method Corrective Actions
It indicates that the
data stored in ROM
has been damaged. All
objects of CAN will
return to the default
settings automatically.
This alarm will not occur at the
moment. If it does, please
contact the distributors.
NMT: Reset node or
0x6040.Fault Reset
AL277: Enter the incorrect password when using CANopen object
Causes Checking Method Corrective Actions
When entering
parameters via CAN,
the parameters are
password-protected.
Users have to decode
the password first.
This alarm will not occur at the
moment. If it does, please
contact the distributors.
NMT: Reset node or
0x6040.Fault Reset
AL283: Forward Software Limit
Causes Checking Method Corrective Actions
Forward Software Limit
Forward Software Limit is
determined by the position
command, not the actual
feedback position. It is because
the command will arrive first and
then the feedback. When the
protection function is activated,
the actual position might not over
the limit. Therefore, setting an
appropriate decelerating time
could satisfy the demand. Please
refer to the description of
parameter P5-03.
NMT: Reset node or
0x6040.Fault Reset

Table of Contents

Other manuals for Delta ASDA-M Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-M Series and is the answer not in the manual?

Delta ASDA-M Series Specifications

General IconGeneral
BrandDelta
ModelASDA-M Series
CategoryServo Drives
LanguageEnglish

Related product manuals