EasyManua.ls Logo

Delta ASDA Series - Page 243

Delta ASDA Series
274 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ASDA Series Application Note Chapter 4 Application Techniques
March, 2015 4-5
Jump to execute the
third CMP function
This will be
executed
after the 3
rd
compare
value is
written to
data array.
PR
#36
(I)
Write
Delay = 0
P4-06 = 0x2
Setup DO status
Select the jump path
PR
#37
(I)
PR
#38
(I)
Write
Delay = 0
P6-91 = 39
Jump
Delay = 0
PR#22
This will be
executed
after the 4
th
compare
value is
written to
data array.
PR
#39
(I)
Write
Delay = 0
P4-06 = 0x0
Setup DO status
Select the jump path
Write
Delay = 0
P6-91 = 30
PR
#40
(I)
Figure 4.1.3 System PR Configuration

Table of Contents