2 Functions of Devices in DVP-PLC
DVP-PLC Application Manual
2-44
Special
M
Function
ES
EX
SS
SA
SX
SC
EH
EH2
SV
Off
Ø
On
STOP
Ø
RUN
RUN
Ø
STO
P
Attribute Latched Default
M1303 High/low bits exchange for XCH instruction
Off - - R/W NO Off
M1304* Enabling force On/Off of input point X
Off - - R/W NO Off
M1305
Reverse operation of the 1
st
group pulse CH0 (Y0,
Y1) for PLSV/DPLSV/DRVI/DDRVI/DRVA/DDRVA
instruction
Off - - R NO Off
M1306
Reverse operation of the 2
nd
group pulse CH1 (Y2,
Y3) for PLSV/DPLSV/DRVI/DDRVI/DRVA/DDRVA
instruction
Off - - R NO Off
M1310*
Immediately disabling Y10 pulse output (for
SC_V1.4 and above)
Off Off - R/W NO Off
M1311* Disabling Y11 pulse output (for SC_V1.4 and above)
Off Off - R/W NO Off
M1312 Controlling start input point of C235
Off - - R/W NO Off
M1313 Controlling start input point of C236
Off - - R/W NO Off
M1314 Controlling start input point of C237
Off - - R/W NO Off
M1315 Controlling start input point of C238
Off - - R/W NO Off
M1316 Controlling start input point of C239
Off - - R/W NO Off
M1317 Controlling start input point of C240
Off - - R/W NO Off
M1320 Controlling reset input point of C235
Off - - R/W NO Off
M1321 Controlling reset input point of C236
Off - - R/W NO Off
M1322 Controlling reset input point of C237
Off - - R/W NO Off
M1323 Controlling reset input point of C238
Off - - R/W NO Off
M1324 Controlling reset input point of C239
Off - - R/W NO Off
M1325 Controlling reset input point of C240
Off - - R/W NO Off
M1328 Enabling start/reset of C235
Off - - R/W NO Off
M1329 Enabling start/reset of C236
Off - - R/W NO Off
M1330 Enabling start/reset of C237
Off - - R/W NO Off
M1331 Enabling start/reset of C238
Off - - R/W NO Off
M1332 Enabling start/reset of C239
Off - - R/W NO Off
M1333 Enabling start/reset of C240
Off - - R/W NO Off
M1334*
EH/EH2/SV: stopping the 1
st
group pulse output
CH0 (Y0, Y1)
SC_V1.4 and above: selecting Y10 pulse output
stop modes
Off - - R/W NO Off
M1335*
EH/EH2/SV: stopping the 2
nd
group pulse output
CH1 (Y2, Y3)
SC_V1.4 and above: selecting Y11 pulse output
stop modes
Off - - R/W NO Off

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta DVP-PLC and is the answer not in the manual?

Delta DVP-PLC Specifications

General IconGeneral
ManufacturerDelta Electronics
ModelDVP-PLC
CategoryController
Humidity5% to 95% RH, non-condensing
Programming LanguageLadder Diagram (LD), Instruction List (IL), Sequential Function Chart (SFC)
CPU TypeVarious, depending on the specific model within the DVP series (e.g., ES2, EX2, SX2, SA2, EH3, etc.)
Operating TemperatureTypically 0°C to 55°C (32°F to 131°F)
Storage TemperatureTypically -25°C to 70°C (-13°F to 158°F)