2 Hardware Specifications and Wiring
DVP-PM Application Manual
2-23
Wiring of DVP-10PM with Yaskawa servo drive:
X4
X6
Y10+
Y10-
Y11+
Y11-
Y0
C0
Shielded cable
MPG pulses
A-phase
X10+
X10-
X11+
PLS
B-phase
X11-
+24V
24V
0V
SIGN
/SIGN
/PLS
24VDC
CLR
/CLR
Y12+
Y12-
Y13+
Y13-
Y1
C1
X0
X2
Y14+
Y14-
Y15+
Y15-
S/S
Y2
(CLR2)
C2
7
11
12
8
Y16+
Y16-
Y17+
Y17-
Y3
(CLR3)
C3
S/S
24VDC
S/S
X1
X3
S/S
X5
S/S
X7
24VDC
24VDC
24VDC
Yaskawa servo drive
14
15
PLS
SIGN
/SIGN
/PLS
24VDC
CLR
/CLR
7
11
12
8
Yaskawa servo drive
14
15
PLS
SIGN
/SIGN
/PLS
24VDC
CLR
/CLR
7
11
12
8
Yaskawa servo drive
14
15
PLS
SIGN
/SIGN
/PLS
CLR
/CLR
7
11
12
8
Yaskawa servo drive
14
15
24VDC24VDC24VDC
+-