11 G-code Application
DVP-PM Application Manual
11-19
a.Call OX0 subroutine
b. Call OX1 subroutine
c. Call OX2 subroutine
Note: Do not set up M1036 (continuous interpolation) before this step, otherwise the loaded data will be
G/M codes with continous interpolation.
4. Enable the dispensing operation: Execute the G/M codes in CAM chart. Work modes of 3 axes should be
set up first and select the CAM chart to be executed. Set D1846 = H2000 to enable cyclic E-CAM. When
the operation in CAM chart is completed, M1793 will be rising-edge triggered.
(1) Set up work modes of 3 axes: if the work modes are set up as H1000 already, skip this step.
(2) Enable the dispensing operation by executing OXn subroutine.