Chapter 12 Description of Parameter SettingsME300
Rated Power for a Permanent Magnet Synchronous AC Motor
Default: Depending on the
motor power
Settings
0.00–655.35 kW
Sets the rated power for the permanent magnet synchronous motor. The default is the drive’s
power value.
Rated Speed for a Permanent Magnet Synchronous AC Motor
Default: 2000
Settings
0–65535 rpm
Number of Poles for a Permanent Magnet Synchronous AC Motor
Default: 10
Settings 0–65535
Stator Resistance for a Permanent Magnet Synchronous AC Motor
Default: 0.000
Settings
0.000–65.535 Ω
Permanent Magnet Synchronous AC Motor Ld
Default: 0.00
Settings 0.00–655.35 mH
Permanent Magnet Synchronous AC Motor Lq
Default: 0.00
Settings 0.00–655.35 mH
Ke parameter for a Permanent Magnet Synchronous AC Motor
Default: 0
Settings 0–65535 V/krpm