Chapter 7 Optional AccessoriesME300
7-36
Installation
(Frame A model as an example)
1. As shown on the right figures, fix the iron plate on the AC
motor drive.
Torque value:
Frame Screw
Torque
A M3.5 6–8 kg-cm / [5.26.9 lb-in.] / [0.590.78 Nm]
B M4 6–8 kg-cm / [5.26.9 lb-in.] / [0.590.78 Nm]
C M4 6–8 kg-cm / [5.26.9 lb-in.] / [0.590.78 Nm]
D M3 4–6 kg-cm / [3.55.2 lb-in.] / [0.390.59 Nm]
Figure 7-26
2. After selecting a suitable R-clip according to the wire gauge
used, fix the R-clip on the shield plate.
Screw
Torque
M4 6–8 kg-cm / [5.26.9 lb-in.] / [0.590.78 Nm]
Figure 7-27
Table 7-39
Dimensions of EMC Shield Plate
Figure 7-28
Model
Dimensions of Shield Plate
mm [inch]
a b
MKM-EPA 69.3 [2.73] 80.0 [3.15]
MKM-EPB 67.7 [2.67] 79.7 [3.14]
MKM-EPC 78.0 [3.07] 91.0 [3.58]
MKM-EPD 103.4 [4.07] 97.0 [3.82]