Error
Code
DPMS Update Error Display Details of Error code Coping strategies
A1
E t h e r I M G * * * m i n
C o n n e c t i o n F a i l A 1
IP Address acquisition failure
(Time Out).
Check the network connection. Update
in an environment where there is a
small network load.
A2
E t h e r I M G * * * m i n
L o g i n f a i l e d A 2
Login incorrect notication DPMS
connection.
Check the network connection. Update
in an environment where there is a
small network load.
A3
E t h e r I M G * * * m i n
S e r v e r i s b u s y A 3
Server congestion notication by
DPMS connection.
Check the network connection. Update
in an environment where there is a
small network load.
A4
E t h e r I M G * * * m i n
C o n n e c t i o n F a i l A 4
Connection failure notication
DPMS connection.
Check the network connection. Update
in an environment where there is a
small network load.
A6
E t h e r I M G * * * m i n
U p d a t i n g f a i l A 6
Error notication received while
requesting Firmware Info.
Turn on the power again. Update will
start automatically.
Update in an environment where there
is a small network load.
A7
E t h e r I M G * * * m i n
U p d a t i n g f a i l A 7
Time Out while obtaining Firm-
ware information.
Turn on the power again. Update will
start automatically.
Update in an environment where there
is a small network load.
AE
E t h e r I M G * * * m i n
D o w n l o a d f a i l A E
Error(NG) notication received
while requesting Firmware Down-
load.
Turn on the power again. Update will
start automatically.
Update in an environment where there
is a small network load.
AF
E t h e r I M G * * * m i n
D o w n l o a d f a i l A F
Error(ServerBusy) notication re-
ceived while requesting Firmware
Download.
Turn on the power again. Update will
start automatically.
Update in an environment where there
is a small network load.
B0
E t h e r I M G * * * m i n
D o w n l o a d f a i l B 0
Error(Connect failure) notication
received while requesting Firm-
ware Download.
Turn on the power again. Update will
start automatically.
Update in an environment where there
is a small network load.
B1
E t h e r I M G * * * m i n
D o w n l o a d f a i l B 1
Error in Firmware Download (Time
Out).
Turn on the power again. Update will
start automatically.
Update in an environment where there
is a small network load.
B2
E t h e r I M G * * * m i n
U p d a t i n g f a i l B 2
Error notication received after
rewriting CX870 / CY920 Firm.
Turn on the power again. Update will
start automatically.
Update in an environment where there
is a small network load.
B3
E t h e r I M G * * * m i n
U p d a t i n g f a i l B 3
Error in Firmware Update (Time
Out).
Turn on the power again. Update will
start automatically.
Update in an environment where there
is a small network load.
B4
E t h e r I M G * * * m i n
U p d a t i n g f a i l B 4
Failed to transit to Boot Loader
Mode.
Initialize the unit and try updating
again.
B5
E t h e r I M G * * * m i n
U p d a t i n g f a i l B 5
Failed to transit to Application
Mode.
Initialize the unit and try updating
again.
93