BHT-604Q
“3: LIGHT”
Set whether the INDICATOR LED light illuminates or not when the trigger switch is depressed.
“0”: Illuminates
“1”: Illuminates
“2”: OFF
“4: SENSOR OFF TIME”
Set the sensor off time
Press [
] to decrease the setting value and [ ] to increase the setting value.
OFF time setting range: 0~255 Default value : 255
“5: SENSOR OFF TIME 2”
Set the time from close to sensor off
Press [
] to decrease the setting value and [ ] to increase the setting value.
OFF time setting range: 0~255 Default value : 0
[5] Setting the communication environment
The communication environment settings following system initialization are follows.
Do not change these settings unless necessary.
Item Default
Interface used Optical (infrared interface port)
Communication protocol type Ymodem protocol
Infrared interface port
TRANSMIT SPEED Baud rate 115200 Bps
PROTOCOL Protocol options SERIAL No.: ON (Adds serial numbers to data
blocks.
)
H. PARITY: ON (Adds horizontal parity.)
LINKUP TIME: 30 seconds
FIELD SPACE: ignore (Trim)
Connector interface port
TRANSMIT SPEED Baud rate
115200 Bps
PARITY BIT (Vertical parity) None
DATA BIT (Character
length)
8 bits
STOP BIT (Stop bit length) 1 Bit
PROTOCOL (Protocol options) SERIAL No.: ON (Adds serial numbers to data
blocks.
)
H. PARITY: ON (Adds horizontal parity.)
LINKUP TIME: 30 seconds
FIELD SPACE: ignore (Trim)