EN Operation
03/2020 45 / 84
The system is regularly sending results to CVINet.
The purpose is to provide a full traceability even when the network connection is unstable.
1. The system is able to keep a defined number of results previously generated by each tightening unit (typi-
cally 10,000).
The alarm threshold corresponds to the percentage of these results that have not been sent to the server and
stored in the FIFO memory.
2. When option "Block if FIFO is full" is enabled, a tightening unit is locked when the FIFO level is 100%. It
allows to ensure traceability of all generated results. The tightening unit is unlocked when connection is re-es-
tablished and FIFO level is under 100%. When disabled, no lock is set when FIFO level is 100%, and traceabil-
ity of all results is not ensured.
Tap this icon to validate.
Operating Instructions
How to select another Pset or Assembly Process
Tap this button on the front panel to display the start screen.
Go to this type of display.
Select the tightening unit.
Tap this icon to display the list of Assembly Processes available.
Tap this icon to display the list of Psets available.
Select the Pset or Assembly Process in the list.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Desoutter CONNECT Series and is the answer not in the manual?

Desoutter CONNECT Series Specifications

General IconGeneral
BrandDesoutter
ModelCONNECT Series
CategorySwitch
LanguageEnglish

Related product manuals