EN Service
03/2020 65 / 84
When the date of the next calibration is reached, a pop-up appears on the tool display asking to perform the cali-
bration.
Calibration is performed by Desoutter technicians only.
Contact your Desoutter representative to get more information and support.
Monitoring the tool counters
Go to the start screen and tap this icon.
Tap Tool > Counters.
The total counter gives the number of tightenings and run reverses above the tool min. torque since the manufactur-
ing date.
The partial counter gives the number of tightenings and run reverses since the last reset.
Monitoring the tool temperature
Go to the start screen and tap this icon.
Tap Tool > Monitoring.
Tap this icon.
Select the tightening unit.
When the alarm is reached, a pop-up appears on the tool display. The tool is locked because the motor is too hot.
Leave the tool until the temperature decreases.
Press the trigger from time to time to check if the tool is still locked.