EN Service
03/2020 55 / 84
Service
About features
How to read the status of features
Status Description
Not active The feature is configured in the Tightening unit settings but NOT activated in the
pane "Current configuration".
Active The feature is configured in the Tightening unit settings AND active in the pane "Cur-
rent configuration".
Available The feature is NO MORE configured in the Tightening unit settings AND NOT ac-
tive in the pane "Current configuration".
How to add a feature
The following procedure is valid for any kind of feature.
The example described here is about adding the feature Up to 50 Psets.
Launch CVI CONFIG.
Go to the tree view.
Select CONNECT.
Select Tightening unit - 51.
Create 10 Psets.
Reminder: you can create up to 10 Psets without adding UVs to CONNECT. From the 11th Pset, you will have
to purchase the feature Up to 50 Psets.
Add 1 additional Pset.
See that Pset 11 is not active.
Go to the tree view and click Feature management.
See the feature Up to 50 Psets is not active.
Click this icon to update the product.
Click "Check UV amount".
If necessary, fill in the RIM with UVs as described in chapter Rebalancing UV to the RIM [Page57].
Click this icon to update CVI CONFIG.
Go to the tree view and click Feature management.
The number of UVs available is now displayed.
Go to the pane Current configuration on the top and click the feature to select it.
Click this icon.