Operation EN
46 / 84 03/2020
or
Tap this icon to search for a Pset not displayed in the list.
Tap this icon to type directly the Pset number in the digital keyboard.
Tap this icon to validate.
How to perform actions on the on-going Assembly Process
At any time during the process, you can do the following actions.
• Abort
• Increment the batch
• Decrement the batch
• Reset the batch
• Reset the retries
How to display and read results
Displaying the results
Go to the start screen and tap this icon.
A green line indicates that the report is OK.
A red line indicates that the report is NOK.
The line turns grey when you select it.
There are 2 lines per result:
• The first line shows the result number and the date and time of the result.
• The second line shows the number of the tightening unit and the torque/angle values.
Up to 20,000 results can be saved per tightening unit.
Use the arrows to scroll the list.
The last results are displayed, the most recent being on the top.
The number of results is displayed on the top.
Tap this icon up to select another tightening unit.