Service and Maintenance
6.7 Accessories
I
6.7.1
Battery
6.7.1.1
Check
Battery
and
Cable
Connections
1©125
89510
6.7.1.2
Check
Electrolyte
Level
6.7.1.3Check
Electrolyte
Density
..q
a
a
N
@
Keep battery clean and
dry.
Undo dirty clamps.
Clean terminal posts
(+
and -) and clamps
of the battery, and grease with acid-free
and acid-resistant grease.
When reassembling, ensure that clamps
make good contact. Tighten clamp bolts
hand-tight.
Remove sealing caps
1.
If testers 2 are present:
Electrolyte level should reach the base of
these.
Without testers:
The electrolyte level should be 10-15
mm
above the top of the plates.
If necessary, top up with distilled water.
Screw sealing caps back
in
.
Measure the electrolyte densityofindividual
cells with a commercial hydrometer.
The hydrometer reading (see table on
following page) indicates the battery's state
of
charge. During measurement, the
temperature
of
the electrolyte should pref-
erably
be
20°C.