9.9 Electrical Supply:
Only sealed batteries with built in fuse may be used.
Vertical Tail Fin Battery: Optional. Only batteries according to drawing
No. 3BR-199 are approved for use.
Battery in baggage compartment: Optional. Fixing to landing gear box only
9.10 Equipment, not being part of minimum equipment:
Transponder: Units approved according to TSO, JTSO or ETSO for use in
airplanes can be installed.
Installation of transponder and transponder antenna must be accomplished
according to technical note DG-G-03.
Other equipment as gliding computers or loggers: These instruments can
be installed, as long as it is guaranteed that they themselves or their effect
on the aircraft do not impair safe operation.
Caution: When additional instruments are installed after production, these must
be properly secured as long as they are not installed to a manufacturer provided
position.
Electrical instruments must be connected via appropriately dimensioned fuses,
current for one instrument must not exceed 3A.
After installation a new weighing report must be filed.