9. PROGRAMMING THE PRINTOUTS
It is possible to programme 30 different formats to be linked to 11 print functions:
- “S.F.01” function >> print key
- “S.F.02” function >> partial total
- “S.F.03” function >> general total
-
For the complete list of the functions and the linking of the formats, see the 14 “PRINTOUTS” section of the USER
MANUAL.
During the printing, the indicator uses the format linked to that printout.
It is possible to configure the formats:
- through the Dinitools™ software for PC, and transmitted to the indicator through the serial line; it is necessary that
the print format number (“Print Format Number”) is a value between 1 and 30 to indicate the format to be overwritten.
Once the formats are configured one should carry out the linkages of the interested functions (USER MAN.REF.).
- manually from the indicator by entering in the SEtuP >> SEriAL >> Prn.FMt step inside the SET-UP environment.
MANUAL CONFIGURATION OF THE PRINT FORMATS
Each format is made up of a maximum of 2048 memory storages (only the first 1000 are manually modifiable from the
indicator), which, when programmed, these will produce the desired printout; in each line one can enter (through a 3-digit
code, from 300 onwards) a command named “print block”, which will produce a certain type of printout, for example:
PRINT NET WEIGHT (code 301), which will print the net weight value, the unit of measure and the CR or CR LF to go to
the next line.
Or it is possible to print a single alphanumeric character, entering the relative ASCII code in the line (from 0 to 255).
To configure a print format:
- Enter in the SEtuP >> SEriAL >> Prn.FMt parameter.
- The display shows:
C.F. XX in which:
XX indicates the number of the format to be modified (from 01 to 30)
- Select the print format to be configured using the arrow keys and press the ENTER key
- Once entered in a format (for example C.F. 01), the display shows:
XXX.YYY in which:
XXX is number of the line which one is programming.
YYY is the entered code (from 0 to 255 the ASCII code is printed, from 300 onwards the relative block is
printed).
- Select the line to be programmed using the arrow keys and press the ENTER key
- The display shows “CHANGE” for an instant and onwards:
XXX in which:
XXX is the value to be modified.
- Enter a value and press the ENTER key to confirm; the C key clears the entered value and if pressed again it cancels
the operation.
- If a print block with parameters from 600 onwards has been entered, after having pressed the ENTER key the displays
shows:

Table of Contents

Other manuals for Dini Argeo 3590EXP Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dini Argeo 3590EXP Series and is the answer not in the manual?

Dini Argeo 3590EXP Series Specifications

General IconGeneral
BrandDini Argeo
Model3590EXP Series
CategoryAccessories
LanguageEnglish

Related product manuals