3590EKR, 3590EXP, 3590EXT, 3590 EBOX, CPWE, CPWET series indicator E-AF03_05.01_14.07_EN_T.doc
9.1 PROGRAMMING EXAMPLE
One programmes a format to be linked to a PRINT key function (S.F.01 function) in this way:
MARIO ROSSI SRL
Date – time
Gross weight
Tare weight
Net weight
3 blank lines
Print end
After having entered in the SET-UP environment, follow the procedures below:
- 082 (letter “R”) Enter in the SEtuP >> SEriAL >> Prn.FMt parameter.
- Select the print format to be configured through the arrow keys and press the ENTER key.
- Select the line to be programmed through the arrow keys and press the ENTER key.
- The display shows the first line to be programmed; enter the 077 code (ASCII relative to the letter “M”); confirm with
ENTER.
- The display shows the following line; enter the 065 code (ASCII relative to the letter “A”); confirm with ENTER.
- Repeat the operations by entering the following codes:
082 (letter “R”)
073 (letter “I”)
079 (letter “O”)
032 (space)
082 (letter “R”)
079 (letter “O”)
083 (letter “S”)
083 (letter “S”)
073 (letter “I”)
013 (terminator CR)
032 (space)
013 (terminator CR)
379 (prints date – time)
013 (terminator CR)
032 (space)
013 (terminator CR)
302 (prints gross weight)
013 (terminator CR)
301 (prints net weight)
013 (terminator CR)
303 (prints tare weight)
013 (terminator CR)
032 (space)
013 (terminator CR)
032 (space)
013 (terminator CR)
032 (space)
013 (terminator CR)
300 (print end) ** It is possible to enter the print end also with the F3 key **
- Press the C key to exit the programming: the display shows “SAVE?”, confirm with ENTER (one goes back into the
“SERIAL” parameter).
- Exit the SETUP environment of the instrument by pressing the C key various times: the display shows “SAVE?”, confirm
the changes made with ENTER (the instrument returns to weighing).