Perform the following operations and checks every 6 months according to intensity of use of
the automation.
Without 230 V~ power supply and batteries:
- Clean and lubricate the moving parts (the carriage guides and the floor guides).
- Check the belt tension.
- Clean sensors and photocells.
- Check the stability of the automatic system and make sure that all screws are correctly tight-
ened.
- Check the alignment of the doors, the closing positions and the correct introduction of the
blocking device.
Connect the 230 V~ power supply and batteries:
- Check that the blocking system is working correctly.
- Check the stability of the door and that the movement is regular and without friction.
- Check that all command functions are operating correctly.
- Check the correct functioning of the photocells.
- Check that the door’s developed powers are in accordance with applicable regulations.
7. Routine maintenance plan
NOTE: for spare parts, see the spares price list.
For repairs or replacements of products only original spare parts must be used.
The installer shall provide all information relating to automatic, manual and emergency
operation of the motorised door or gate, and provide the user with operating instructions.
The installer must prepare the maintenance log, which will indicate all the interven-
tions of ordinary and extraordinary maintenance carried out.