8
IP1950EN - 2013-09-13
5.2 VALOR T box fastening
KPAM45
KPAM45
255
160
70 max 70 max
90
38
2728
H
12
145
+/- 8
HM=H+16
+/- 6 +/- 6
Unless otherwise specified, all measurements are expressed in millimetres (mm).
The figure shows the measurements for wall mounting the VALOR H automation considering that
the door wings are made of DITEC PAMH60 series profiles.
If the PAMH60 door wing has lead-shielding (e.g. radiology department) refer to the measure-
ments marked [*].
Fix the box with M6 Ø12 steel plugs or 6MA screws. Distribute the fixing points approx. every 800
mm.
Make sure that the box is level and its top surface is perpendicular with the floor and not deformed
lengthwise with the shape of the wall. If the wall is not straight and smooth, the box must be fixed
to metal plates.
WARNING: The fastening of the box to the wall must be suitable in order to sustain the weight of
the door wings.
Wiring passage