6
IP1950EN - 2013-09-13
4. Standard installation
Ref. Code Description
0 VALOR Operator
1 Drive unit
2 EL20 Control panel
3 AL2 Transformer
4 VALABE
VALABC
Emergency batteries (optional)
No-break batteries (optional)
5
PAS024AMW (microwave+infrared), or
PASAA2 (only infrared)
Combined sensor for opening and safety during closing
external side
6A
PAS024AMW (microwave+infrared), or
PASAA2 (infrared only)
Combined sensor for opening and safety during closing
internal side (operator)
or
6B
PASM24W (microwave), or
PASM243 (microwave), or
PASS24 (microwave), or
PASS24W (microwave), or
PASA (infrared)
}
+ PASAT3I
(infrared)
Opening sensor (a) + Safety during closing sensor (b) inter-
nal side (inside the operator’s housing)
7
PASAT3
PASAT3I
Safety during opening sensor (outside or inside the opera-
tor’s housing)
8 VALSB
LOKSBM
Integrated release handle
Release handle
9 COME - COMHK Functions selector switch
10 CELPR Photocells (NOT ACCORDING TO STANDARD EN 16005)
11 MD1 Display
12 PFP1 - PFP2 - PDP1 - PDP2 Open push buttons
A Connect the power supply to an approved omnipolar switch with an opening distance of the contacts of at least
3mm (not supplied). The connection to the mains must be made via an independent channel, separated from
the connections to command and safety devices.
A
11
3
1
2
4
6A
6B
7
0
8
9
10
12
7
GND
5
a
b
6B