The given operating and performance features can only be guaranteed with the use of
DITEC accessories and safety devices.
5. Installation of the automation
5.1 VALOR box fastening
70 max
0KP515AB
+/- 8
+/- 6
10 HM = H + 18
145
Unless otherwise specified, all measurements are expressed in millimetres (mm).
The VALOR automation wall fixing measurements are illustrated in the diagram, considering that
the door wing profiles are not of our production.
If the door wings are made with DITEC profiles of the PAM series: refer to the measurements in
the related manuals.
WARNING: if the door wings are fitted with a break-out device, use the carriages with brackets
with 3 fixing points.
Fix the box with M6 Ø12 steel plugs or 6MA screws. Distribute the fixing points approx. every 800
mm.
Make sure that the box is level and its top surface is perpendicular with the floor and not deformed
lengthwise with the shape of the wall. If the wall is not straight and smooth, the box must be fixed
to metal plates.
WARNING: The fastening of the box to the wall must be suitable in order to sustain the weight of
the door wings.
Wiring passage