Default parameters:
Parameter ranges:
Parameter Laser System
D320 i-Tech 10mm Scan head
StepPeriod [ms] 30
JumpDelay [ms] 100
MarkDelay [ms] 100
PolygonDelay [ms] 20
LaserOffDelay [ms] 110
LaserOnDelay [ms] 80
MaxVectorLength [mm] 0.25
LaserPower [%] 95
JumpSpeed [bit/ms] 7000
MarkSpeed [bit/ms] 6000
Parameter Laser System
D320 i-Tech 10mm Scan head
StepPeriod [ms] 10..100
JumpDelay [ms] 0..500
MarkDelay [ms] 0..500
PolygonDelay [ms] 0..500
LaserOffDelay [ms] 10..500
LaserOnDelay [ms] 10..500
MaxVectorLength [mm] 0..100
JumpSpeed [bit/ms] 100..16000
MarkSpeed [bit/ms] 100..16000