Maintenance Section
-134-
When Required
You must read and understand the warnings and instructions contained in the Safety section of this manual, before
performing any operation or maintenance procedures.
Battery Terminal - Clean, Inspect
WARNING
Batteries give off flammable fumes that can explode.
Do not smoke when observing the battery electrolyte
levels.
Electrolyte is an acid and can cause personal injury
if it contacts skin or eyes.
Always wear protective glasses when working with
batteries.
Typical Example Diesel Engine Truck
1. Clean the top of the battery and terminals.
2. Check terminals for corrosion. Coat terminals with
heavy grease.
SCR Cleaning - DeSOx
SCR Cleaning - DeSOx Display Pop-up
In order that the SCR system may maintain its exhaust
cleaning efficiency at a proper level, it should be
periodically initialized“SCR cleaning.”
DOC & SCR Position
SCR Cleaning switch Position
SCR Cleaning switch

Table of Contents