Maintenance Section
-152-
2. Rotate the element slightly to separate it from its base
and remove it from the air cleaner housing.
3. Clean and inspect the element or replace with a new
element. See topic, “Cleaning Primary Filter
Elements”.
4. Clean the inside of air cleaner housing and the cover.
Inspect all connections between the air cleaner and
engine. Check intake hose for cracks, damage and
loose clamps. Tighten or replace parts as necessary
to prevent leakage.
NOTICE
Do not allow dirty air to enter the intake hose when
cleaning the inside of the air cleaner housing.
5. Check the air cleaner housing for loose latches.
6. Reset the air cleaner service indicator.
7. Install the air filter element.
8. Install the cover and tighten the cover latches.
9. Start the engine and observe the position of the
indicator. If the indicator shows RED after the
installation of the primary element, install another
clean or a new element or, replace the secondary
element. See topic, “Air Intake System - Change” in
Every 1000 Service Hours or 6 months section.
10. Stop the engine and close the hood and seat
assembly.
Cleaning Primary Filter Elements
WARNING
Pressure air can cause personal injury.
When using pressure air for cleaning, wear a
protective face shield, protective clothing and
protective shoes.
The maximum air pressure must be below 205 kPa
(30 psi) for cleaning purposes.
NOTICE
Do not clean the elements by bumping or tapping them.
Inspect filter elements after cleaning. Do not use a filter
with damaged pleats, gaskets or seals.
When cleaning with pressure air, use 205 kPa (30 psi)
maximum pressure to prevent filter element damage.
When cleaning with pressure water, use 280 kPa (40 psi)
maximum pressure to prevent filter element damage.
Have spare elements on hand to use while cleaning used
elements.
The primary element should be replaced after a year’s
service or after cleaning no more than 6 times.
Air-205 kPa (30 psi) Maximum Pressure
Direct air on the inside and outside of the element along
the length of the pleats. Check the element for any tears,
rips or damage.