EasyManua.ls Logo

Dormakaba 705 - 3.8 Users

Dormakaba 705
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
dormakaba USA Inc. System User Guide 7040.0320 | 19
b. Navigate through the information on screen with the arrow buttons
4. During a Holiday, the lock will not open at any time on the specified day(s). To view holiday(s), do the following:
a. Select View Holiday
b. Navigate through the information on screen with the arrow buttons
Note: If Time/Date is not set after a prolonged power outage, access time lock schedules cannot be enforced and may result in the
inability to open the lock until the time/date is set.
3.8 Users
3.8.1 Lock User Types
There are three types of users, each with different capabilities. The sub-sections outlined below cover each Lock User Type and their
respective functions.
3.8.1.1 Master
• There will always be 1 Master User per safe lock
• Combination length is always 8 digits and is not modified by the combination length system setting
• The default factory combination is 1-2-3-4-5-6-7-8
• The User ID is always 00 and cannot change
• Cannot open the lock directly
• Can change their combination either via the Keypad or the LA GARD Software client
• Needs to authenticate with an old combination prior to being allowed to update their combination
• The forced-change-on-first-use rule does not apply to Master combinations
• The Master combination should be changed from the default value prior to adding any other non-Master Users to the System
3.8.1.2 Manager
• Should be enabled within the system, but not required
• Multiple Managers may be defined depending on the lock type
• Only Master-authenticated users can modify the Manager’s settings
• The combination is in the format of 2 ID digits plus 6 to 9 combination digits
• The combination length required for the system applies to Manager(s) and all other users
• The combination length will be the same for all Users in the system, including Manager(s)
• May change their combination via the Keypad
• May open the lock if the access settings are enabled for the lock
• May set other access Users’ one-time-combo via the Keypad menus or via the LA GARD Software client
• May be granted Time Delay Override if Time Delay option is applied to a safe lock

Table of Contents