Follow these steps to set the options:
1. Navigate through the Main Menu and select System.
2. Select TD Cnt Mode from the sub-menu.
3. Select either Delay Period or Confirm Window.
4. Select one of the following choices and press the return key:
a. Off
i. the time remaining or accumulated will not display; only information on what period it is in will be
displayed
b. Count Up
i. the count will start from 00:00 and count up until the period expires
c. Count Down
i. the time will start at the period length and count down to 00:00
3.11.1.3 Enable/Disable Time Delay – Non-Display Keypad
Note: This function is not available on the 701 series of Keypad,
Follow these steps to Enable/Disable Time Delay on a non-Display Keypad:
1. Using the Keypad, input #72 + Authorized ID and Combination + Delay Period (00 to 99 minutes) + Open Window (01 to 60
minutes) + Return Key.
2. The Keypad will beep three times and flash a green LED once complete.
3.11.2 Open a Lock During Time Delay
3.11.2.1 Open a Lock During Time Delay – Display Keypad
Follow these steps to open a safe lock during a Time Delay on a Display Keypad:
1. Using the Keypad, input the User ID and Combination.
2. For multi-lock systems, select the corresponding lock number on the keypad. Otherwise, skip to the next step.
3. Lock # Start Delay will appear on screen and provide timer feedback. The type of feedback depends on the setting for count
feedback (the time may count down, up, or only show time remaining). There is no continuous feedback; a key must be
pressed to check the Time Delay status. When a key is pressed on a Display Keypad, the ‘most urgent’ lock will be displayed.
a) Most Urgent Lock: In a single lock system, the Time Delay status is for a single lock, in a multi-lock system, the
status will be provided for i) the lock with the least amount of time remaining in the confirmation window, or ii) if
no lock is in the confirmation window, then the lock with the least amount of time remaining will be present in the
delay window
4. Once the Time Delay period expires, Lock # status Confirm appears on screen.
5. If a lock is in the confirmation window, it can be opened. Press a key to exit the Time Delay Status.
6. Input the User ID and Combination.
7. From the sub-menu, select Open Lock.
a) For multi-lock systems, select the corresponding lock number on the keypad. If the selected lock has Time Delay
enabled and i) is not already in Time Delay, Time Delay will start for the lock, and ii) is already in Time Delay and
the confirmation window, then the lock will open
8. The lock will open and the screen will display Lock Open. After a few seconds, the lock will close.
3.11.2.2 Open a Lock During Time Delay – Non-Display Keypad
Note: This function is not available on the 701 series of Keypad,