dormakaba USA Inc. System User Guide 7040.0320 | 32
1. Audits.
2. Open count.
3.10.3.1 Master Reset
This method requires knowledge of the Master combination. In a multi-lock System, Lock #1 must be reset last. Follow these steps to
perform a Master reset:
1. For Display Entries, do the following:
a. Enter the Master ID and Master Combination.
b. From the Main Menu, navigate through the options to select System.
c. From the options, select Locks.
d. Select Reset.
e. All locks installed within the System will be listed. An X indicates no lock installed. Press the corresponding number
key to select a Lock.
f. After resetting all other locks, or if the primary lock is the only one installed, Confirm Reset will appear on screen.
Select Yes. Success will appear on screen when the lock is reset. If the primary lock is reset, the Keypad will then
reset. If other locks are reset, the Keypad will return to the Locks section on screen.
Note: An ‘X’ in the lock selection screen indicates the lock cannot be reset. The lock might not be connected, or not
installed, or is the primarily lock and the only one that can be reset. When the primary lock is the only lock installed, a
prompt will appear instead of lock selection to confirm the reset.
2. For Non-Display Entries, do the following:
a. Enter this # Command to perform a Master reset: #25<Master PIN><rtn key>.
b. If the Master combination is unknown, proceed to the next section to perform a Mechanical Reset.
3.10.3.2 Mechanical Reset
A mechanical reset can be done utilizing the LA GARD Reset Box. Refer to the Reset Box User Guide (Document #7039.0320) for
more information. The Mechanical Reset is not UL evaluated.
It is important after the reset operation, that the Reset Box is disconnected from the operational lock. If the safe door is closed with
the reset box attached, the lock will no longer open.