SECTION 5 - TROUBLESHOOTING
5-5
SmartDate 5 06/08
Fault Message 1007 - Printhead Resistance Not Set
Description The printhead resistance requires setting.
Possible
Causes
A new printer PCB has been fitted.
Remedial
Action
Set the printhead resistance level.
Fault Message 1008 - Tension Not Calibrated
Description The Tension sensor requires calibration.
Possible
Causes
A new printer PCB has been fitted.
Remedial
Action
Calibrate the Tension sensor.
Table 5– 1: Fault Messages