SECTION 5 - TROUBLESHOOTING
5-9
SmartDate 5 06/08
Fault Message 1204 - Printhead Voltage Fault
Description The Printhead voltage is out of range.
Possible
Causes
Faulty printhead.
Faulty printhead ribbon cable.
Faulty printer PCB
Remedial
Action
Check the printhead and ribbon cable for damage.
Try fitting a different printhead or ribbon cable.
Replace the printer PCB
Fault Message 1205 - Ribbon Fault (unexpected movement)
Description
Possible
Causes
Ribbon not fitted correctly in the cassette.
Remedial
Action
Remove the cassette, re-fit the ribbon. Re-insert the
cassette to clear the fault.
Fault Message 1206 - Low Air Pressure
Description
Possible
Causes
The air pressure has dropped.
Remedial
Action
Check the air pressure and increase if required.
Fault Message 1207 - Multiple Missed Prints
Description
Possible
Causes
Print trigger sensor is detecting multiple signals.
Remedial
Action
Check that the sensor is correctly fitted.
Fault Message 1208 - End of Ribbon
Description
Possible
Causes
The ribbon has run out.
Remedial
Action
Fit a new ribbon.
Table 5– 1: Fault Messages