EasyManuals Logo

Dräger Evita 4 Repair Instructions

Dräger Evita 4
89 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #2 background imageLoading...
Page #2 background image
For internal use only. Copyright reserved.
Contents
GBR5664500T055664800IVZ.fm
5664.500/800 Evita 4/Evita 2 dura 02/98 Repair Instructions Page 2
Dräger Medizintechnik
D
3.4.2 External DS mode using PC...................................................................... 30
4 Paediatric Flow PCB Option for Evita 4 as of SW 2.20 31
4.1 Power Supply to the Paediatric Flow PCB ..............................................................31
4.2 Connector Pin Assignment of the Paediatric Flow PCB ......................................31
4.3 Replacing the Paediatric Flow PCB ......................................................................... 33
5 CO2 Carrier PCB 34
5.2 CO2 Carrier PCB Connector Pin Assignment ...................................................... 35
5.3 Replacing the CO2 Carrier PCB .............................................................................. 38
5.4 Tests possible in DS mode ......................................................................................... 38
5.4.1 Diagnosis mode............................................................................................ 38
5.4.2 External DS mode using PC...................................................................... 38
5.5 Conversions ................................................................................................................... 39
5.5.1 Replacing CO2 Carrier PCB According to IDM No. 3 (Evita 4) ....... 39
5.5.2 Conversion due to Error Message “Ext. Battery reversed poles”
IDM No. 2 (Evita 2 dura) or IDM No. 19 (Evita 4)40
5.5.3 Conversion for Device Error 02.71.003 IDM No. 2 (Evita 2 dura) or IDM
No. 19 (Evita 4)41
6 Power Supply PCB (CO
2
measurement) 42
6.1 Power Supply to the Power Supply PCB ................................................................ 42
6.2 Connector Pin Assignment on the Power Supply PCB ....................................... 42
6.3 Measuring the Voltages on the Power Supply PCB ............................................. 43
6.3.1 Printed Circuit Board on Extender Board............................................... 43
6.3.2 Printed Circuit Board in the Evita............................................................. 43
6.4 Test Points on the Power Supply PCB .................................................................... 44
6.5 Replacing the Power Supply PCB ........................................................................... 45

Table of Contents

Other manuals for Dräger Evita 4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dräger Evita 4 and is the answer not in the manual?

Dräger Evita 4 Specifications

General IconGeneral
BrandDräger
ModelEvita 4
CategoryMedical Equipment
LanguageEnglish

Related product manuals