REGARD 8-Input 4-20 Module & 8-Channel Display Card (ATEX Version)
Issue 2. October 2011
31
Set user-definable text
User-definable text can be used to enter non-standard gas name or measurement unit.
Text entered is used when USER setting is chosen in command 04–0 or 04–1.
PRESS DISPLAY
• Select command 52–4
R
USER
Waiting for text entry: first character flashing
????
• Enter text. e.g. mg/l
R
mg/l
(Press or to select next or previous character)
• Select next / previous head
52–4:h2
• Confirm selection and exit command
R
52–4
Gas level display on / off
Normal display of gas level can be disabled for any head, if required.
PRESS DISPLAY
• Select command 60–1
R
DISPLAY
• Select ON for normal display, or OFF to disable
display of gas level
h1:ON
• Confirm selection and exit command
R
60–1:h1