7
System Output Ratings
Other Devices
Read the manufacturer’s literature carefully to determine the max-
imum current requirement (during activation or alarm) and use
this value for loading calculations. Do not allow connected
devices to exceed the system capabilities during any possible
operational mode.
2.6 Assigning Zones to Zone Expanders
The main panel contains zones 1 to 8. Additional zone expanders
may be added to increase the number of zones on the system.
Each zone expander consists of one group of 8 zones. Each
module must be set to assign the specific zones to the expander.
To do this, set the jumpers located on the expander to the proper
settings (see chart below).
NOTE:
PC5108 v1.0 and lower modules can only support the first
32 zones on the PC1616/PC1832/PC1864 system. PC5108 v1.0 and
lower, PC5700 enrolls as two expander modules.
NOTE: Do not use PC5108 v1.0 and v2.0 simultaneously on the
same PC1616/PC1832/PC1864 panel.
NOTE: Before a zone expander will work properly, you must set
the jumpers so the panel can determine the correct zone assign-
ment.
The following are jumper settings for different zone assignments
for PC5108 v2.0 modules. If you need to enroll PC5108 v1.0 or
PC5700 modules, refer to the appropriate module Installation
Sheet for the correct jumper settings.
The following is a diagram of the PC5108 zone expander module
and where the jumper switches are located. Refer to the PC5108
Installation Instruction sheet for the module for more information.
NOTE:
Only jumpers J1, J2, and J3 determine the zone assign-
ment for the module.
2.7 Keypad Assignment
There are 8 available slots for keypads. LED and ICON keypads
by default are assigned to slot 1. LCD keypads are assigned by
default to slot 8. Keypads can each be assigned to a different slot
(1 to 8) which offers two advantages. The panel can supervise the
keypad connection to indicate a trouble condition if it is removed.
Also keypads can be assigned to operate on a specific partition,
or to operate as a global keypad.
How to Assign Keypads
1. Enter Installer Programming
2. Press [000] for Keypad Programming
3. Press [0] for Partition and Slot Assignment
4. Enter a two digit number to specify the partition and slot
assignment.
FSA-410 xS/xST 4-wire Smoke Detector 75mA
FSA-410 xRS/
xRST/xLRST
4-wire Smoke Detector 90mA
PK5500 LCD Keypad 125mA
PK5501 ICON Keypad 125mA
PK5508 8 Zone LED Keypad 125mA
PK5516 16 Zone LED Keypad 125mA
RFK5500 LCD Keypad with Wireless Module 135mA
RFK5501 ICON Keypad with Wireless Module 135mA
RFK5508 8 Zone LED Keypad With Wireless
Module
135mA
RFK5516 16 Zone LED Keypad With Wireless
Module
135mA
LCD5500Z LCD Keypad 125mA
LCD5501Z ICON Keypad 125mA
LCD5501Z32-433 ICON Keypad with Wireless Module 260mA
LCD5511 ICON Keypad 85mA
LED5511 8 Zone LED Keypad 100mA
Skyroute Cellemetry Communicator 30mA
PC5532Z 32 Zone LED Keypad 85mA
PC5516Z 16 Zone LED Keypad 85mA
PC5508Z 8 Zone LED Keypad 85mA
PC5100 Addressable Multiplexed Loop
Interface Module
40mA
PC5108 Zone Module 35mA
PC5132 Wireless Module 125mA
PC5200 Output Module 20mA
PC5204 Output Module 20mA
PC5208 Output Module 50mA
PC5320 Multiple Receiver Interface Module 55mA
Escort5580(TC) Voice Prompting Module 150mA
PC5400 Printer Module 65mA
PC5401 Data Interface Module 35mA
PC5700 Fire Module 150mA
PC5900 Audio Verification Module 50mA
PC5904 Central Station Talk/Listen Module 175mA
PC5921 Intercom Audio Station 20mA
PC5921 EXT Door Box Audio Station 20mA
PC5921 EXT/R Door Box Audio Station 35mA
TL250 T-Link Ethernet Communicator 275mA
VVM110 Video Verification Module 490mA
Device Output Rating (12VDC)
PC1616
PC1832
PC1864
AUX: 500mA (700 mA for UL/ULC).
Subtract the listed rating for each keypad,
expansion module and accessory connected to
AUX or Keybus.
BELL: 700 mA. Continuous Rating.
2.0 A. Short Term. Available only with standby
battery connected.
PC5200 AUX: 1.0 A.Continuous Rating. Subtract for each
device connected.
3.0 A. Short Term. Available only with stand-by
battery connected.
PC5204 AUX: 1.0 A. Continuous Rating. Subtract for each
device connected.
3.0 A. Short Term. Available only with stand-by
battery connected.
PC5208 AUX: 250 mA. Subtract for each device connected.
Subtract the total load on this terminal from the
PC1616/PC1832/PC1864 AUX/Keybus output.
PC5108 VAUX: 100 mA. Subtract for each device connected.
Subtract the total load on this terminal from the
PC1616/PC1832/PC1864 AUX/Keybus output.
Device Description
Max Rating
@12V
DC
Module Jumpers System Zones Assigned
J1 J2 J3
ON ON ON Zones disabled
OFF ON ON Zones 09 - 16
ON OFF ON Zones 17 - 24
OFF OFF ON Zones 25 - 32
ON ON OFF Zones 33 - 40
OFF ON OFF Zones 41 - 48
ON OFF OFF Zones 49 - 56
OFF OFF OFF Zones 57 - 64

Table of Contents