30
[020] - Keypad Zone Assignment
Each keypad has a zone input to which a device (i.e. a door con-
tact) can be connected (see section 2.11 ‘Keypad Zone/PGM‘ on
page 10 for wiring information).
Once the keypad zones are installed. Enter section [020], there
are eight 2 digit entries, repersenting the zone for keypads in slot
1 to 8. Enter the 2-digit zone designated for each keypad (slot)
from 01-64.
[021] - Eighth System Option Codes
8 Remote Reset After
Second Activation
ON Remote Reset After Second Activation Only A remote reset will occur only after a second confirmed
alarm, which is generated by the activation of a different zone, or the same zone with double hit enabled.
This second activation must tie in with the Burglary verified timer. If this timer expires, then further two
activations in different zones will be required before the keypads are locked out. The system will be locked
out until a 4 digit Reset code that is provided by the Installer/Central Station is entered on a keypad.
OFF Reset Required After One Activation If remote reset is enabled when an Alarm occurs on a burglary
zone, the system will be locked out until a 4 digit Reset code that is provided by the Installer/Central Station
is entered on a keypad. If the Duress code is used to disarm the partition, then the system will not be
locked out. In the Disarmed state, only Audible 24Hr Burglary zones, Audible 24Hr Latching Tamper zones,
and Audible 24Hr zone on PGM 2 will cause the panel to be locked out. To get the Reset code from the
Installer/Central Station, the end user must provide the Installer/Central Station with the corresponding Sys-
tem Lock code, which will be displayed on the keypad.
Option Definition On/Off Description
Option Definition On/Off Description
1 Access Codes
Blocked During
Entry Delay
ON Access code entry blocked during Entry Delay During entry delay, access codes will not be accepted by
the system. Only keyswitches can be used to disarm the system.
NOTE: If the system is *9 armed the user will not be able to disarm with a wireless key.
OFF Access code entry NOT blocked during Entry Delay An access code can be used to disarm the system
during entry delay.
2 EN Entry Delay ON EN Entry Procedure The following zone type alarm will follow bell delay if a zone violation occurs while
entry delay is active on the partition: Instant, Interior, Interior Stay/Away, Delay Stay/Away, 24 Hr Supervi-
sory, 24 Hr Buzzer, 24 Hr Burg, 24 Hr Holdup, 24 Hr Gas, 24 Hr Heat, 24 Hr Medical, 24 Hr Panic, 24 Hr
Emergency, 24 Hr Sprinkler, 24 Hr Water, 24 Hr Freeze, 24 Hr Latching Tamper, Interior Delay, Day Zone,
Instant Stay/Away, 24 Hr Bell/Buzzer, 24 Hr Non-Latching Tamper, Night Zone, Audible 24 Hr PGM Input.
The transmission delay attribute must be enabled for all burg type zones when this feature is ON. Trans-
mission delay and bell delay times should be programmed to be longer than entry delay. When entry delay
ends, the bell delay will be cleared and the siren will activate. Any burg type zone will follow transmission
delay when the zone alarm occurred during the Entry Delay. When entry delay expires, the control panel
will delay the communication of the alarm for an additional 30 seconds to allow the user time to disarm
before the signal is sent. The police code or burglary verified timer will not begin until the additional 30
second transmission delay has expired without a valid disarming procedure. If a zone violation occurs but
entry delay is not active the bell will sound and the alarm will be communicated immediately depending on
the zone type tripped.
NOTE: The transmission delay attribute must be enabled for all burg type zones when this fea-
ture is on.
NOTE: Transmission delay and bell delay times should be programmed to be longer than entry
delay.
OFF Standard Entry Delay If bell delay is activated, an alarm from a burglary type zone will follow bell delay
regardless of entry delay being active. If transmission delay is activated, the communication of an alarm
from a zone with the tx delay attribute enabled will be delayed regardless of entry delay being active.
3 Keypad Blanking
Timing Options
ON 5-second Keypad Blanking. The panel will turn off all lights and LCDs on the keypads if no key is
pressed for 5 seconds when the Keypad Blanking Option is on. See option 3 Section [016].
OFF 30-second Keypad Blanking. The panel will turn off all lights and LCDs on the keypads if no key is
pressed for 30 seconds when the Keypad Blanking Option is on - Option 3 Programming Section [016].
UK
EN
C