EasyManua.ls Logo

DSC PC1832 - Opening (Disarming) Reporting Codes Ac- Cess Codes 1 to 32; Miscellaneous Opening (Disarming) Reporting Codes; Maintenance Alarm Reporting Codes; Miscellaneous Maintenance Reporting Codes

DSC PC1832
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
37
[342]-[343] - Opening (Disarming) Reporting Codes Access
Codes 1 to 32
The panel will transmit an
Opening Reporting Code to indicate
partition(s) is disarmed. A different reporting code can be trans-
mitted for each user code, partition master code and system mas-
ter code to identify who armed the partition(s).
[344] - Miscellaneous Opening (Disarming) Reporting Codes
Opening by Duress Code 33/34: This Reporting Code will be
transmitted in addition to the duress reporting code if a Partition(s)
is disarmed using a Duress Code
Opening by Master or Supervisory Code: The panel will trans-
mit this reporting code to indicate a Partition(s) is armed. A differ-
ent reporting code can be transmitted for each User Code,
Supervisory Code and System Master Code to identify who
armed the Partition(s).
Auto Arm Cancellation: This reporting code is transmitted when
the Auto Arming sequence is canceled or Postponed
Special Opening: A Special Opening Reporting Code will be
transmitted if the Partition(s) is disarmed using any of the follow-
ing methods:
Disarming using the Maintenance Code
Disarming via the DLS Software
Disarming via keyswitch
[345] - Maintenance Alarm Reporting Codes
Battery Trouble Alarm: the panel will transmit a Battery Trouble
Alarm Reporting Code when the backup battery drops below 11.5
V
DC.
AC Failure Trouble Alarm: the panel will transmit an AC Failure
Trouble Alarm Reporting Code when the AC to the panel is lost
and the AC Failure Communication Delay timer expires.
Bell Circuit Trouble Alarm: a Bell Circuit Trouble Alarm Reporting
Code will be transmitted immediately if an open condition is mea-
sured on the Bell Output of the main panel.
Fire Trouble Alarm: a Fire Trouble Alarm Reporting Code will be
transmitted immediately when an open condition is measured on
any Fire type zone.
Auxiliary Power Supply Trouble Alarm: the Auxiliary Power Sup-
ply Trouble Alarm Reporting Code will be transmitted if the AUX
output is shorted.
TLM Trouble: a TLM Trouble Reporting Code can only be trans-
mitted if an alternate communicator is being used. The panel will
only transmit the signal after the time programmed for the TLM
Trouble Delay.
General System Trouble: a General System Trouble Reporting
Code will be transmitted if the panel detects any of the following:
AC Power Failure
Low Battery
AUX Output Trouble
Output #1 on the PC5200/PC5204 Power Supply/Output
Module.
T-Link Troubles
General System Supervisory Trouble: a General System Super-
visory Trouble Reporting Code will be transmitted if any module
goes missing from the Keybus. If the module is a zone expander
the panel will also transmit the
Zone Expander Supervisory Alarm
Trouble
Reporting Code.
[346] - Maintenance Alarm Reporting Codes
Battery Trouble Restoral: the Battery Trouble Restoral Report-
ing Code will not be transmitted until the battery has been
charged over 12.5 V
DC.
AC Failure Trouble Restoral: the AC Failure Trouble Restoral
Reporting Code will be transmitted once AC power has been
restored for the amount of time programmed for AC Failure Com-
munication delays.
Bell Circuit Trouble Restoral: the Bell Circuit Trouble Restoral
Reporting Code will be transmitted as soon as the open condition
on the bell output is corrected.
Fire Trouble Restoral: the Fire Trouble Restoral Reporting Code
will be transmitted when the correct resistance value is measured
on any Fire type zone.
Auxiliary Power Supply Trouble Restoral: the panel constantly
checks the AUX output, when the excessive current draw is
removed the panel will reset the output and transmit an Auxiliary
Power Supply Trouble Restoral Reporting Code.
TLM Restoral: the TLM Restoral Reporting Code will be transmit-
ted immediately after the trouble is restored.
General System Trouble Restoral: a General System Trouble
Restoral Reporting Code will be transmitted when the panel
detects none of the following:
AC Power Failure
Low Battery
AUX Output Trouble
Output #1 on the PC5200/PC5204 Power Supply/Output
Module.
T-Link Troubles
General System Supervisory Restoral: the General System
Trouble Restoral Reporting Code will be transmitted when the
control panel detects all modules enrolled on the keybus
[347] - Miscellaneous Maintenance Reporting Codes
Telephone Number 1 (2) FTC Restore: if the panel fails to trans-
mit information to the central station it will display a failure to com-
municate trouble condition. The panel will transmit a Phone
Number 1 Failure to Communicate Reporting Code or a Phone
Number 2 Failure to Communicate Reporting Code the next
time it calls the central station. The panel will transmit the old
events, followed by the failure to communicate, followed by the
new events.
Event Buffer 75% Full: if the Event Buffer is uploaded on a regu-
lar basis an Event Buffer 75% Full Reporting Code can be trans-
mitted to warn that the Buffer is almost full.
NOTE:
For EN panels, the Event Buffer 75% Full will not be
logged.
DLS Lead In: the DLS Lead In Reporting Code will only be trans-
mitted if the DLS Call Back feature is being used (See Section 5.8
"Downloading"). Before the panel calls the computer back it will
call central station and transmit the reporting code to indicate a
download session is about to begin.
DLS Lead Out: after a downloading session is attempted and/or
completed, the panel will transmit a DLS Lead Out Reporting
Code.
Zone Fault Alarm: the Zone Fault Alarm Reporting Code will be
transmitted when there is a short detected on any DEOL zone
and/or a loss of supervisory on a wireless zone.
Zone Fault Restore: the Zone Fault Restore Reporting Code will
be transmitted when the fault condition on the zone is corrected.
Delinquency Code: the Delinquency reporting code is sent
whenever the panel is not armed within the number of days pro-
grammed for the Delinquency Transmission Delay.
General Zone Low Battery Alarm: the panel will transmit a
General Zone Low Battery Alarm Reporting Code when a wire-
less detector indicates a low battery condition and the delay pro-
grammed in "Zone Low Battery Transmission Delay" expires.
General Zone Low Battery Restoral: the General Zone Low
Battery Restoral Reporting Code will be transmitted when the low
battery condition on all wireless zones is corrected. The specific
zone that caused the trouble will be stored to the Event Buffer.
[348] - Test Transmission Reporting Codes
Walk Test End: the walk test end reporting code will be transmit-
ted when a walk test is terminated
Walk Test Begin: the walk test begin reporting code will be trans-
mitted when a walk test is initiated
Periodic Test Transmission with Trouble - the panel can be
programmed to transmit a Periodic Test Transmission with Trou-
ble Reporting Code in place of the standard Periodic Test Trans-
mission if any of the following conditions exist.

Table of Contents

Other manuals for DSC PC1832