43
[381] - Second Communicator Option Codes
[382] - Third Communicator Option Codes
Option Communicator Code On/Off Description
1 Opening After Alarm Keypad
Ringback
ON Opening After Alarm Keypad Ringback Enabled When the Opening After Alarm reporting code
is successfully transmitted to a programmed telephone number, the keypad will sound a series of 8
beeps to confirm to the end user that the Opening After Alarm Code was sent and received. This
Ringback will occur for each Opening After Alarm code successfully reported.
OFF Opening After Alarm Keypad Ringback Disabled When the Opening After Alarm reporting
code is successfully transmitted to a programmed telephone number, the keypad will not sound
ringback.
2 Opening After Alarm Bell
Ringback
ON Opening After Alarm Bell Ringback Enabled. When the Opening After Alarm reporting code is
successfully transmitted to a programmed telephone number, the Bell will sound a series of 8
squawks to confirm to the end user that the Opening After Alarm Code was sent and received. This
Ringback will occur for each Opening After Alarm code successfully transmitted.
OFF Opening After Alarm Bell Ringback Disabled When the Opening After Alarm reporting code is
successfully transmitted the system will not perform a ringback.
3 SIA Reporting Codes ON SIA Sends Programmed Rep. Codes This option is for use with the SIA communication format.). If
00 is programmed in the reporting code section, the event will not be communicated. When this
option is ON and there is a valid reporting code programmed in the reporting code section, the pro-
grammed reporting code will be transmitted. If FF is programmed as a reporting code, the event will
not be communicated.
Reporting Code Entry Option ON Option OFF
00 No Transmission No Transmission
FF No Transmission Auto Rep Code sent
01-FE 01-FE sent Auto Rep Code sent
NOTE: If the automatic SIA or automatic Contact ID reporting formats are not used, report-
ing codes must be programmed.
OFF SIA Sends Automatic Rep. Codes When this option is OFF and there is a valid reporting code (01-
FE) or FF programmed in the reporting code section, the panel will transmit an automatic reporting
code for SIA only. This would be used when automatic reporting codes are required but there is a
requirement for a different reporting code (i.e. Pager Format, etc.).
4 Closing Confirmation ON Closing Confirmation Enabled When a Closing reporting code is successfully transmitted to a pro-
grammed telephone number, the keypad will sound a series of 8 beeps to confirm to the end user
that the Closing Code was sent and received.
OFF Closing Confirmation Disabled There will be no keypad ringback when a Closing reporting code
is successfully transmitted to a programmed telephone number.
5 Talk/Listen Options for
Phone Number One/Three
ON Talk/Listen (PC59XX) on Phone #1/3 Enabled If Talk/Listen is requested for an event by the
PC59XX, the panel will request the session on the next communication on Phone Number 1/3 (via L-
Block) to the central station.
OFF Talk/Listen (PC59XX) on Phone #1/3 Disabled The panel will not request a Talk/Listen session for
an event even if the PC59XX has requested it.
6 Talk/Listen Options for
Phone Number Two
ON Talk/Listen (PC59XX) on Phone #2 Enabled If Talk/Listen is requested for an event by the PC5900,
the panel will request the session on the next communication on Phone Number 2 (via L-Block) to
the central station.
OFF Talk/Listen (PC5900) on Phone #2 Disabled The panel will not request a Talk/Listen session for an
event even if the PC59XX has requested it.
7 Contact I.D. Reporting Codes ON Contact I.D. Uses Programmed Reporting Codes The Contact I.D. communications format will
use programmed reporting codes when transmitting to central station.
NOTE: If the automatic SIA or automatic Contact ID reporting formats are not used, report-
ing codes must be programmed.
OFF Contact I.D. Uses Automatic Reporting Codes The Contact I.D. communications format will use
the automatic reporting codes as shown in Appendix C when transmitting to central station.
8 For Future Use
Option Communicator Code On/Off Description
1 Contact I.D. Partial Closing
Identifier
ON Partial Closing Identifier = 5 Contact I.D. uses ‘5’ as the Identifier for the Partial Closing event.
OFF Partial Closing Identifier = 4 Contact I.D. uses ‘4’ as the Identifier for the Partial Closing event.
2 Walk Test Communication ON Zone Alarms Communicate during Walk Test Enabled Zone alarms that occur during Walk Test
will communicate if programmed to do so.
OFF Zone Alarms Communicate during Walk Test Disabled Zone alarms that occur during Walk Test
will not communicate even if programmed. This option is defaulted OFF.
3 Communications Cancelled
Message
ON Communications Cancelled Message Enabled The “Communications Cancelled” (LCD) or “CC”
(ICON) message will be displayed if alarms are acknowledged during the Transmission Delay time.
This message will be displayed for 5 seconds on all keypads on the partition. The acknowledgment
can be from an access code, disarm function key, or a keyswitch zone.
OFF Communications Cancelled Message Disabled The “Communications Cancelled” message will
not be displayed. This option is defaulted OFF.
4 Call Waiting Cancel ON Call Waiting Cancel Enabled The Call Waiting dialing string programmed in Section [304] will be
dialed before the first attempt of each phone number. All subsequent dialing attempts to the same
phone number will not use the Call Waiting Cancel dialing string.
OFF Call Waiting Cancel Disabled The Call Waiting dialing string will not be dialed. This option is
defaulted OFF.
NOTE: A call waiting cancel on a non-call waiting line will prevent successful connection
to the central station.

Table of Contents