32
[022] - Ninth System Option Codes
[023] - Tenth System Option Codes
Option Definition On/Off Description
1 Access Code
Required for [*][1],
[*][2], [*][3]
ON Access code is required for [*][1], [*][2] and [*][3] menu options In order to access the [*][1] bypass
menu, [*][2] trouble menu, or [*][3] alarm memory menu a valid access code is required. Events will also be
generated and logged, thus identifying the user.
NOTE: You must have a version LCD5500 3.40U or greater keypad, PK55XX or RFK55XX Key-
pad.
NOTE: This feature is not supported by the PC5400.
OFF No access code required for [*][1], [*][2], [*][3] menu options No access code is required In order to
access the [*][1] bypass menu, [*][2] trouble menu, or [*][3] alarm memory menu.
2 Keypad Blanking
while Armed
ON Keypad Blanking while Armed Keypad will blank after the programmed time (Section [021], Option 3)
when the system is armed.
NOTE: This feature will only blank after exit delay has expired.
OFF Keypad follow regular blanking option Keypad will blank after the programmed time (Section [021],
Option 3) when the system is armed or disarmed.
3 Auto-Arming/Force
Arming Open Zones
ON Auto-Arming/Force Arming Open Zones All zones will be force armed during an autoarm regardless of
the force arm attribute on the zone.
OFF Auto Arming follows Force Arming Attribute Only zones with the force arm attribute enabled will be
force armed during an autoarm.
4 Master Code
Bypasses Holdup
ON Master code bypasses holdup zones only Attempting to bypass a hold-up zone with any other access
code will generate error tone.
OFF Any code can bypass hold up zones Any code can bypass Hold up zones
5 Time Limit for PGM
05, 06, 17, 18
ON Time Limit Enabled for PGM 05, 06, 17, 18 Setting Keypad Blanking Option ON - Option 5 Programming
Section [022] - may satisfy this requirement. The panel will turn off all lights and LCDs on the keypads if no
key is pressed for 30 or for 5 seconds – depending on the status of toggle option 3 in Programming Section
[021] irrespectively of the armed or disarmed state of the Intruder alarm system. Implementation of the
option 3 in Programming Section [021] shall allow the installer to enable/disable the 5 seconds time limit
for Programmable Output Options 05 (Armed Status), 06 (Ready to Arm), 17 (Away Armed Status) and 18
(Stay Armed Status).
OFF Time Limit Disabled for PGM 05, 06, 17, 18 Listed PGM’s will not turn off (time out)
6 RF Delinquency
Enable
ON RF Delinquency Enabled If any wireless zone supervisory transmission is not received by the PC5132 dur-
ing a 15-minute period, the PC5132 will place the panel into Not Ready To Arm mode. In the armed state,
the Zone faults will generate tamper alarms. The panel will generate a silent trouble (NO trouble beeps but
the Trouble LED is turned ON) called “RF Device Delinquency”, that’s only viewable in [*][2] (Trouble Mem-
ory). The user can override the condition and arm the panel by using the feature.
OFF RF Delinquency Disabled The system will not indicate an RF Delinquency when a zone supervisory trans-
mission is not received during a 15 minute period.
7 Open Zones Cancel
Arming
ON Open Zones Cancel Arming If there is an open zone at the end of exit delay, arming of the system will be
canceled.
OFF Open Zones Cancel Arming Disabled If there is an open zone at the end of exit delay the system will
arm with the zone open.
8 Audible Exit Delay
for Stay Arming
ON Audible Exit Delay for Stay Arming When the system is armed in Stay mode the exit delay will be
sounded by 1 beep every 3 seconds.
OFF Stay Arming is Silent When the system is armed in Stay mode the exit delay will be silent.
EN
EN
EN
EN
Option Definition On/Off Description
1 [F] Key Beeps ON [F] Key Beeps Only Whenever the [F] is pressed you will only get the acknowledge beeps from the key-
pad. The bell will not sound.
OFF [F] Key Beeps and Sounds Bell [F] key will beep the keypad and trigger the bell output
2 200 Baud Open/
Close Identifier
Toggle ON/OFF
ON 200 Baud Open/Close Identifier Toggle ON 200 Baud Open Close Identifier is 2 for arming 1 for disarm-
ing
OFF 200 Baud Open/Close Identifier Toggle OFF 200 Baud Open Close Identifier is 1 for arming 2 for dis-
arming
3 Test Transmission
While Armed Only
ON Test Transmission While Armed Only The Panel will send a test transmission at the programmed interval
and time if the system is armed.
OFF Test Transmission While Armed or Disarmed The Panel will always send a test transmission at the pro-
grammed interval and time.
4 Transmission
Counter
ON Transmission Counter in Hours The Panel will send a test transmission after the programmed number of
hours in the test transmission cycle (Section [377], Option 7)
OFF Transmission Counter in Days The Panel will send a test transmission after the number of days pro-
grammed in the test transmission cycle (Section [377], Option 7) at the programmed time.
5 Stay/Away Toggle
Option
ON Switching from Away to Stay Disabled The system can not be switched from Away to Stay mode by
pressing the [Stay] function key.
OFF Away to Stay Toggle Option Permitted The system can be switched from Away to Stay mode by press-
ing the [Stay] Function key.
6 2-way Audio Discon-
nect
ON 2-way Audio Will Not Disconnect For New Event The system will not disconnect the 2-way audio ses-
sion if a new event occurs on the system.
OFF 2-way Audio Will Disconnect For a New Event The system will disconnect the 2-way audio session if a
new event occurs on the system.