27
[016] - Fourth System Option Codes
[017] - Fifth System Option Codes
6 Master Code ON Master Code Not User Changeable The Master Code (Access Code 40) may not be changed by the user,
and may only be programmed in the Installer’s Programming Mode.
OFF Master Code User-Changeable The Master Code may be programmed by the user using the [*][5][Mas-
ter Code] command. The Master Code may also be programmed in the Installer’s Programming Mode.
7 Telephone Line Mon-
itor
ON Telephone Line Monitor enabled The TLM function will be active and the system will indicate a Trouble
#3 condition when using the [*][2] View Trouble Conditions Command.
NOTE: For IMQ-Security certified installations the TLM option shall be enabled.
OFF Telephone Line Monitor disabled The TLM function will be shut off and telephone line troubles will not
be indicated by the system.
8 Telephone Line Mon-
itor Audible Trouble
ON TLM Audible When Armed When the system is disarmed, a telephone line monitor trouble will generate
a trouble indication as described above. If the system is armed, a telephone line monitor trouble will gener-
ate an audible alarm on the bell or siren for the duration programmed for Bell Timeout or until an access
code is entered to disarm.
OFF TLM Trouble Only A telephone line trouble will generate a trouble indication, the Trouble LED will come
ON, and the keypad sounder will beep until a key is pressed.
Option Definition On/Off Description
Option Definition On/Off Description
1 AC Trouble Display ON AC Trouble Displayed If AC power fails, the condition will be reported to the monitoring station and will
be indicated as a Trouble condition on the system Keypads.
OFF AC Trouble Not Displayed If AC power fails, the condition will be reported, but the Trouble light will not
be indicated on the system keypads. If [*][2] is entered to view the system troubles, Trouble #2 will still be
displayed.
2 AC Trouble Flash ON Trouble Light Flashes if AC Fails When AC power is lost from the system, the “Trouble” light will flash in
the base “Ready” and “Armed” mode within 30 seconds from after power is lost. When AC restores, the
“Trouble” light will stop flashing within 30 seconds. If enabled, this option will override the AC display option.
OFF Trouble Light Does Not Flash on AC Fail When AC power is lost from the system, the “Trouble” light
will not flash.
3 Keypad Blanking ON Blank Keypad When Not Used If no keys are pressed for 30 seconds, all keypad lights except backlighting
(if enabled) will be shut OFF until the next keypress, Entry delay, Audible Alarm or keypad buzzer condition.
NOTE: Keypad function keys will still operate when the keypad is blank, unless the function key
is programmed to require an access code.
NOTE: Keypad Blanking While Armed will override this feature.
OFF Keypad Always Active The keypad lights will remain ON at all times.
4 Keypad Blanking
Restore
ON Access Code Required to remove Keypad Blanking A valid access code must be entered before a
blanked Keypad can be used
OFF Access Code Not Required Pressing any key on a blanked keypad will remove the blanking.
5 Keypad Backlighting ON Keypad Backlighting is Enabled All keypads on the system will have backlighting on all of the time.
OFF Keypad Backlighting is Disabled All keypads on the system will have their backlighting off.
6 Power Save Mode ON Power Save Mode Enabled If AC power fails, all keypad lights including backlighting will be shut OFF. The
keypad lights will come back ON after a keypress, Entry delay, Audible Alarm or keypad buzzer condition
(except Door Chime). The keypad lights will return to the off state after 30 seconds of keypad inactivity.
OFF Power Save Mode Disabled If AC power fails, the keypads will not go into power save mode.
7 Bypass Status
Display
ON Bypass Status Displayed While Armed The Bypass status light will be ON if there are zones bypassed
when the system is armed.
OFF Bypass Status Not Displayed While Armed The Bypass light will be ON only while the system is dis-
armed to indicate that there are bypassed zones on the system. When the system is armed, the Bypass light
will be OFF.
NOTE: The Bypass status LED will be ON if there are Stay/Away zones auto bypassed at the
time of arming regardless of whether or not this option is enabled. This option only enables and
disables manual bypass display.
8 Keypad Tampers ON Keypad Tampers are Enabled All keypads containing Tamper switches will generate Tamper Alarms and
Restores (Sect 338).
NOTE: Not used in North America, ensure that it is disabled.
OFF Keypad Tampers are Disabled The Tamper switches on all keypads will not generate Tamper Alarms.
NOTE: If this option is used, all keypads should be properly installed and secured (tamper
restored) before enabling the option.
Option Definition On/Off Description
1 Wireless Key
Disarming
ON WLS Keys Do Not Use Access Codes The panel will accept the disarm keycode from an unidentified wire-
less key, allowing arming/disarming without a code.
NOTE: This option must be ON when using a PC5132 older than v3.00.
NOTE: When using wireless keys with access codes, if you default the PC1616/PC1832/PC1864,
you should also default the PC5132 (See Section 5.12 Special Installer Functions [996]).
OFF WLS Keys Uses Access Codes The panel will NOT accept the disarm keycode from an unidentified Wire-
less Key. An Access code must be associated to a WLS key for proper operation.(Refer to the PC5132 man-
ual for information on programming wireless keys.)
2 RF Jam Event Log ON RF Jam Log After 5 Minutes The RF Jam Trouble will not log to the event buffer until the 5 minute delay
has elapsed.
OFF RF Jam Log After 30 Seconds The RF Jam Trouble will log to the event buffer after the initial 30 second
delay has elapsed.