36
NOTE:
SIA will use this account code for all Partitions and System
Events! System events will be identified by Nri0, with Partitions 1-8
using Nri1-8.
[311]-[318] - Partition 1-8 Account Codes
These Account Codes are used by the panel when communicat-
ing events for Partitions 1-8 when using formats other than SIA.
NOTE:
All partition account codes are 4 digits in length. Valid
entries are 0000-FFFE.
Reporting Codes
Communicator - Reporting Codes
Unless you are using Automatic Contact ID or Automatic SIA for-
mats, reporting codes must be programmed in order for the panel
to report events to the central station.
Reporting codes are two digits and can use hexadecimal digits A
through F. To disable a reporting code, program it as “FF” (default
setting) or “00”. For a complete description of reporting codes
which can be programmed and lists of automatic Contact ID and
SIA format codes, see section Appendix A: ‘Reporting Codes‘ on
page 56.
[320]-[323] - Alarm Reporting Codes, Zones 1 to 64
The panel will transmit the Zone Alarm Reporting Code for a zone
when the zone goes into alarm. 24-hour type zones will go into
alarm whether the panel is armed or disarmed and report to the
central station. All other zone types will only go into alarm if the
panel is armed.
Reporting codes can be one or two digits and can use HEX digits
(A through F). The following is a description of the different report-
ing codes that can be programmed and when the events will be
reported to central station.
[324]-[327] - Alarm Restoral Reporting Codes, Zones 1 to 64
If the Restoral on Bell Timeout option is selected the panel will
send the Zone Restoral Reporting Code for the zone when the
alarm output times out AND the zone is secure. If the zone is not
secured when the alarm output times out the panel will send the
restoral immediately after the zone is secured.
If the Restoral on Bell Timeout option is not selected the panel
will immediately send the Zone Restoral Reporting Code when
the zone is secured or when the panel is disarmed, regardless if
the alarm output is active or not.
NOTE:
24-hr type zones will report the restoral immediately
after the zone is secured.
[328] - Miscellaneous Alarm Reporting Codes
Duress Alarm: this reporting code will be transmitted to the moni-
toring station whenever a Duress code is used to perform any
function on the system.
Opening After Alarm: this reporting code will be transmitted to
the monitoring station on Opening if an alarm has occurred during
the previous armed period.
Recent Closing: a Recent Closing transmission shall be sent if an
alarm occurs within 2 minutes of an exit time expiration. The
Recent Closing report will be sent for the first alarm only.
Zone Expander Supervisory Alarm: this reporting code is sent
when the system loses communications with any zone Expander
Module (PC5108, PC5132, or Keypad with on-board zone).
Zone Expander Supervisory Restoral: this reporting code is sent
when the system regains communications with all zone Expander
Module (PC5108, PC5132, or Keypad with on-board zone) that
have been enrolled on the system.
Cross Zone/Police Code Alarm: When using Cross Zoning (Sec-
tion 018, Option 6 ON), this reporting code will be sent when two
'crossed' zones go into alarm during the Cross Zone period.
When using Police Code (Section 018, Option 6 OFF), this report-
ing code will be sent when any two zones go into alarm.
If the
Double Hit option has been enabled, this reporting code will
be sent when two zone alarms occur on the same zone and the
Burglary Verified timer has not expired.
NOTE:
Only one reporting code will be sent during each armed to
armed period when using Police Code.
Burglary Not Verified
: this reporting code will be sent after the
burglary verified timer expires after a zone alarm occurs.
Alarm Canceled: this reporting code will be sent if a valid access
code is entered during the Alarm Cancel window. If a valid access
code is entered during this window, then the Alarm Canceled
event is logged and sent. When the central station has acknowl-
edged this reporting code/event, a keypad ring-back will occur.
[329] - Priority Alarm/Restoral Reporting Codes
[F], [A], [P] Alarm: this reporting code will be sent if the [F] [A] or
[P] key is used to generate manual alarms.
Auxiliary Input Alarm: this reporting code will be sent when
PGM2 is being used for two wire smoke detectors and the 2-wire
smoke detector goes into alarm.
[F], [A], [P] Restoral: this reporting code will be sent after the [F]
[A] [P] alarm reporting code is sent.
Auxiliary Input Restore: the panel will transmit this reporting code
when the 2-wire smoke detector has restored after an alarm.
[330]-[333] - Tamper Reporting Codes, Zones 1 to 64
If the panel is programmed for Double EOL zones (See Section 2.10
"Zone Wiring") the panel will report a
Zone Tamper Alarm Reporting
Code if an open condition is present on a zone. A different reporting
code can be programmed for each zone for identification.
[334]-[337] - Tamper Reporting Codes, Zones 1 to 64
The
Zone Tamper Restoral Reporting Code will be transmitted
immediately when the tamper condition is restored.
[338] - Miscellaneous Tamper Reporting Codes
General System Tamper: a General System Tamper Reporting Code
will be transmitted when the tamper zone on any module is vio-
lated.
General System Tamper Restoral: the General System Tamper
Restoral Reporting Code will be transmitted when the tamper
zone on the module is restored.
Keypad Lockout: the panel will transmit the Keypad Lockout
Reporting Code if the lockout is activated.
[339]-[340] - Closing (Arming) Reporting Codes, Zones 1-32
The panel will transmit a Closing Reporting Code to indicate a
Partition(s) is armed. A different reporting code can be transmitted
for each User Code, Partition Master Code and System Master
Code to identify who armed the partition(s).
[341] - Miscellaneous Closing (Arming) Reporting Codes
Closing by Duress Code 33/34: a closing by Duress Code Report-
ing Code will be transmitted in addition to the Duress reporting
code if a Partition(s) is armed using a Duress Code
Closing by Master or Supervisory Code: the panel will transmit a
Closing Reporting Code to indicate a Partition(s) is armed. A dif-
ferent reporting code can be transmitted for each User Code,
Supervisory Code and System Master Code to identify who
armed the Partition(s).
Partial Closing: a Partial Closing Reporting Code will be transmit-
ted if a Partition is armed with zones manually bypassed. The
code will also be transmitted if a Partition Auto Arms with zone(s)
in violation.
Special Closing: a Special Closing Reporting Code will be trans-
mitted if the Partition(s) is armed using any of the following:
Quick Arm
Auto Arm
Arming via the DLS Software
•Arming via Keyswitch
Away Function Key Arming
Arming with the Maintenance Code
Stay Function Key arming
Late to Close: a Late to Close Reporting Code will be transmitted
if a partition isn't armed before the Auto-arm start time when the
late to close option, (Section 017, option 5) is enabled.