54
NOTES
Programming at installation may be subordinate to other UL
requirements for the intended application.
Cross zones have the ability to individually protect the
intended area (e.g., motion detectors, which overlap).
Cross zoning is not recommended for line security Installa-
tions nor is it to be implemented on exit / entry zones.
There is a communication delay of 30 seconds in this control
panel. It can be removed, or it can be increased up to 45 sec-
onds at the option of the end user by consulting with the
Installer.
Do not duplicate any reporting codes. This applies for all
communication formats other than SIA sending automatic
programmed reporting codes.
The control unit must be installed with a local sounding
device and an off-premise transmission for SIA communica-
tion format.
For ULC Listed Fire Monitoring Installations & module
requirements, please refer to the ULC Installation Informa-
tion sheet, part# 29002157.
Use a CSA/cUL transformer, hardwired.
All tamper circuits may be connected to the same zone.
Use ULC-LA for AC Power indication.