Chapter 5 Programming Worksheets
35
[021] Eighth System Options
[022] Ninth System Options
[023] Tenth System Options
[030] Zone Loop Response (Zones 1-8)
Opt Def ON OFF
1
Access Code Entry Blocked During Entry Delay
Access Code Entry Not Blocked During Entry Delay
2
For Future Use
3
For Future Use
4
For Future Use
5
For Future Use
6
Keyswitch Disarming During Entry Delay Only
Keyswitch Disarming at Any Time
7
For Future Use
8
For Future Use
Opt Def ON OFF
1
Access Code Req’d for [][1], [][2], [][3]
No Access Code Req’d for [][1], [][2], [][3]
2
For Future Use
3
For Future Use
4
Master Code Bypasses Holdup Zones Only
Any Code Bypasses Holdup Zones
5
For Future Use
6
RF Delinquency enabled
RF Delinquency disabled
7
For Future Use
8
Audible Exit Delay for Stay Arming
Stay Arming Silent
Opt Def ON OFF
1
Fire Key Beeps Only
Fire Key Beeps and Sounds Bell
2
For Future Use
3
Test Transmission While Armed Only
Test Transmission While Armed/Disarmed
4
Test Transmission in Hours
Test Transmission in Days
5
Switching from AWAY to STAY disabled
AWAY to STAY toggle Option Permitted
6
2-way Audio will Not Disconnect for a New Event
2-way Audio will Disconnect for a New Event
7
Trouble Beeps are Silent*
Trouble Beeps sound every 10 seconds
8
Keyswitch Arm in Away Mode
Keyswitch arms in STAY or AWAY
* This option must be off for UL residential fire applications
Opt Def ON OFF
1
Zone 1 is Fast Loop Response
Zone 1 is Normal Loop Response
2
Zone 2 is Fast Loop Response
Zone 2 is Normal Loop Response
3
Zone 3 is Fast Loop Response
Zone 3 is Normal Loop Response
4
Zone 4 is Fast Loop Response
Zone 4 is Normal Loop Response
5
Zone 5 is Fast Loop Response
Zone 5 is Normal Loop Response
6
Zone 6 is Fast Loop Response
Zone 6 is Normal Loop Response
7
Zone 7 is Fast Loop Response
Zone 7 is Normal Loop Response
8
Zone 8 is Fast Loop Response
Zone 8 is Normal Loop Response

Other manuals for DSC PowerSeries PC1616

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC PowerSeries PC1616 and is the answer not in the manual?

DSC PowerSeries PC1616 Specifications

General IconGeneral
Partitions2
KeypadsUp to 8
Zones6 on-board
PGMs2
Power Supply16.5VAC
Battery Backup12VDC, 4Ah

Related product manuals