EasyManua.ls Logo

DSC T-LINK TL250 - Page 14

DSC T-LINK TL250
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
SIA
DVACS Alarms Examples
Example 1 (DVACS with receiver set as 1 digit line number)
Printer:
Computer:
Example 2 (DVACS with receiver set as 3 digits line number)
Printer:
Computer:
Additional Events:
If the T-Link TL250 transmitter does not receive polls (response) from the panel, the T-Link will gener-
ate the events previously generated by the SG-DVL2A for DVACS panel and restoral.
SIA
Printer:
Computer:
Printer:
Computer:
Standard
Printer:
Computer:
Printer:
Computer:
NOTE: The SG-DRL3-IP will use 10-digit account identifications in it's IP table for DVACS
transmitters. The first four digits represents the receiver and line number originally used on
the SG-DVL2A and are programmed as the first four digits of the T-Link account (refer to
appendix F of SG-DRL3-IP Installation Manual).
NOTE:If the automation protocol in the form of 1RRL, 3RRL is required when using the DRL3-
IP in the DVACS configuration, set DRL3-IP Option [11] =1 and CPM3 Options [10] & [11] = 03
01 Nov 2004-13:50:51-01/02-SG -01-1-0456--Fire Alm Zn999
3011 0456FA 999
01 Nov 2004-13:51:03-01/02-SG -01-001-0456--Medical Alm Zn001
3011 0456MA 001
01 Nov 2004-13:50:51-01/02-SG -01-1-001--Account Absent
3011 0001YC 000
01 Nov 2004-13:50:51-01/02-SG -01-1-001--Account Present
3011 0001YK 000
01 Nov 2004-13:50:51-01/02-SG -01-1-001--IDcde IncResp
1011 001 A 0A
01 Nov 2004-13:50:51-01/02-SG -01-1-001--IDcde Restore
1011 001 R 0A