27
> Press the “Off” or “On” button until the required digit is displayed.
> Press the
“OK” button to confirm the digit.
The next digit flashes on the operator's panel.
> Repeat this procedure until all four digits of the PIN have been changed.
The set PIN is stored; the PIN is requested when the Settings menu and the ECO
menu are selected.
8.2 Change water temperature
Change bath water temperature
> Press the
“OK” button to call up the menu.
> Select Settings > Water > Temperature.
> Press the
“Off” or “On” button until the required temperature is displayed.
> Press the
“OK” button.
The temperature selected is stored and you are returned to the Water sub-menu.
ECO-mode temperature
The ECO-mode temperature can not be changed. It is pre-defined at 2 °C lower than
the temperature of the bath water, which can be changed.
Change standby-mode temperature
The temperature can be set between 15-25 °C/59-77 °F.
> Press the
“OK” button to access the menu.
> Select Settings > Water > Standby Temperature.
> Press the
“Off” or “On” button until the required Standby-mode temperature is dis-
played.
> Press the
“OK” button.
The temperature selected is stored, you are returned to the Water sub-menu.
8.3 Change loop time for water changing
CAUTION
Deactivating water changing can lead to contaminated water.
When water changing is deactivated there is no blending of water in the pipes. The O
3
generator is also switched off. This may lead to deposits in the pipes.
> Do NOT select
“Off” as the loop time.
The loop time is pre-defined to 8:00 and 20:00. If you wish to change it, please note