17.3 Master reset
A master reset resets all parameter values to their factory settings.
Turn off the main switch.
Press the P key and turn on the main switch.
Release the P”key..
Enter code no. 1907”.
Press the E key. The parameter F-100 is displayed.
Press the E key. The value of the parameter F-100 is displayed.
Set the value to 170.
Press the P key twice.
Turn off the main switch.
After a brief waiting period turn the main switch back on.
All parameters have now been restored to their pre-set values.
Caution !
A few parameters, like F-111, F-161, F-170, F-171 and F-190
to F-194 for example, are not affected by a master reset.
All machine-specific parameters must be reset again in
accordance with the parameter sheet.