6.7 Changing the needle with single-needle machines with the hook on the right
Caution! Risk of injury!
Replace the needle with the main switch switched off and the motor
stopped.
Draw the lever (1) in your direction to loosen the screw fixing the
needle.
Remove the needle and insert a new one with the needle scarf (2)
to the right according to the section (3) or (4). The needle may not
be oriented according to the section (5).
Turn the lever (1) back to tighten the needle fixing screw.
Caution! Danger of breakage!
A false orientation of the needle may damage the hook point.