6. TORQ PULSES/REV
Sets an alternate pulses per revolution rate (PPR) for applications that use more than one
transducer. To enable this rate, enable Menu A. Parameter 18 and close TB2-25.
7. CLUTCH MIN RPM
The minimum speed for the clutch.
8. CLUTCH MAX RPM
The maximum speed of the clutch. Please note that proper minimum and maximum values
are necessary for safe and proper use of the drive.
9. MTR NO LOAD AMPS
The no load amp setting for the motor for proper scaling and torque limiting. Consult the
nameplate on the drive for the correct value. Only used if a current transformer is being used
to measure the motor amps.
10. MTR FL. LOAD AMP
The full load amp setting for the motor for proper scaling and torque limiting. Consult the
nameplate on the drive for the correct value. Only used if a current transformer is being used
to measure the motor amps.
11. COAST ENABLE
Allows for bypassing of the deceleration rate by dropping out the output and allowing the
shaft to coast to a stop.
ENABLE
DISABLE (default)
12. LOCAL/REM ENABLE
Allows user to switch between local and remote mode on the keypad. Local corresponds to
functions done on the keypad, while remote corresponds to functions done external to the
keypad (TB2).
ENABLE (default)
DISABLE
13. CURRENT FILTER 1
Adjusts the inner current loop feedback signal (clutch amps) (Default: 16).